Axial fan energy-saving renovation and exhaust design precautions

Axial fans are typically used in high flow and low pressure situations. The axial fan is fixed in place and moves the air. Axial fans are mainly composed of impellers and fan housings. Its structure is simple, but the data requirements are high. The local exhaust hood should be as close as possible to or close to the harmful passive device, resulting in harmful passive restrictions and a small local space. The suction range should be minimized for easy capture and control.


The direction in which the exhaust hood draws in air should be as similar as possible to the direction of contaminated air. Contaminated inhaled air is not allowed to pass through the human breathing area. Full consideration is given to the location and scope of the operator's activities. The hood is simple in design, low cost and easy to install and maintain. The local exhaust hood is set according to the production process and does not affect the seek operation. To avoid interference, the effects of suction flow, airflow and airflow distribution should be minimized.


The gas conveyed by the axial fan should be free of obvious dust, non-stick substances and fibrous substances; the temperature of the direct motor should not exceed 40 °C, the temperature of the belt-driven type should not exceed 60 °C, and the amount of dust transported by the gas should not exceed 150 mg/
m3.

 
The axial fan is mainly composed of impeller, housing, motor, etc., and the bracket is connected with the housing. Among them, the impeller and shell of the anti-corrosion axial fan are made of FRP, and other types of axial fans are generally made of steel plate.


Application of axial flow fan energy-saving transformation: When the axial flow fan starts, the motor current is 5-6 times higher than the rated value, which not only affects the service life of the motor, but also consumes the service life of the motor more powerfully.


The system has a certain motor selection space in the design process, and the motor speed is fixed. However, in practical applications, it is sometimes necessary to operate at lower or higher speeds, so frequency conversion is very necessary.


By changing the input voltage frequency of the device, the frequency converter realizes the soft start of the motor, saves the speed regulation, and provides protection functions such as overcurrent, overvoltage and overload for the equipment.

 
Heat dissipation characteristics of axial fans: We know that the so-called axial fans refer to the blades driving air to flow in the same direction as the shaft, so it is called an axial fan. The square cooling fans produced by Jingyangda Technology are mostly axial fans.


Compact structure, large air volume, low noise is a key indicator, so the commonly used handheld fan is an axial fan, desktop CPU cooling fan is also an axial fan.


Axial fan mold is simple, the cost of opening is low, and the production and assembly process is relatively small, such as China's ceiling fan, floor fan, etc.


Conventional turbofan pressure is not generated by the central part of the fan, but by the rotation of the fan blades. Therefore, no matter how high the speed, there will be no wind under the shaft. But under the fan shaft is the heating core, which is the main heating source. This situation has caused the inherent defects of traditional axial fans: the motor is blocked, and the air flow cannot reach the central part smoothly, resulting in a "blind spot". The presence of blind spots leads to excessive temperature in the core of the radiator, which affects the overall heat dissipation effect of the radiator.